Description
Built for Swine Procedures
Moduflex Optimax for Swine
An Optimax with a deeper canister base, a double canister, a drawer module, and a top shelf for the monitor.
Double
CO2 canister
0.1-4 LPM
Oxygen flowmeter
3 drawers
Module included
75 lb
Machine weight
Overview
Swine cases put a lot of moisture into the breathing circuit, so Dispomed gave this Optimax a deeper canister base where water can collect while the circuit stays clear. A second canister is added for longer cases, a compact module with three drawers keeps tubing, bags, and accessories near the table, and a top shelf holds the patient monitor.
The rest of the machine follows the standard Optimax. Oxygen is set on a 0.1 to 4 LPM flowmeter with a rotating float and large scale, the flush valve is recessed, and the fresh gas outlet sits at the front with a quick-connect fitting, which makes it easy to move to another circuit or to the optional Bain adaptor. The vaporizer mounts on a SELECTATEC-compatible manifold that supports a vaporizer interlock. Standard equipment also includes gauges for circuit and line pressure, a pop-off valve with a momentary close feature, a condensation trap ahead of the soda lime, and a 2.5 meter DISS oxygen supply hose.
The machine is offered with or without a cylinder holder. For general small animal work, see the standard Moduflex Optimax and the rest of our veterinary anesthesia machines.
Key Features
Deeper canister base
Extra depth under the canister gives condensation room to collect.
Double canister
A second canister is fitted for longer swine cases.
Drawer module included
Three drawers in one compact module hold tubing, bags, and accessories.
Top monitor shelf
A shelf on top of the machine holds the patient monitor.
Up to three flowmeters
0.1 to 4 LPM oxygen as standard, with room for oxygen, air, nitrous oxide, or CO2 meters.
SELECTATEC manifold
The vaporizer mounts on a SELECTATEC-compatible manifold with interlock compatibility.
Veterinary Applications
Dispomed built this Optimax for swine surgery and the moisture it brings to the circuit.
- Swine surgery
- Rooms that keep tubing and bags in drawers at the machine
- Setups that run a patient monitor on the machine shelf
- Teams that switch to a Bain circuit through the optional adaptor
Available configurations
| Configuration | Cylinder holder |
|---|---|
| Without cylinder holder | Not fitted |
| With cylinder holder | Small cylinder holder fitted |
Included
Included
- Y patient circuit
- One 2 liter rebreathing bag
- One 3 liter rebreathing bag
- Fresh gas tube
- Krytox grease
- Evacuation tube, 150 cm (5 ft)
Available options
- Up to two small cylinder holders
- Bain circuit adaptor
- 0 to 1 LPM oxygen flowmeter
- Up to three flowmeters (oxygen, air, nitrous oxide, CO2)
- Circuit pressure alarm