DISS Medical Gas Outlet Conversion Kit

Web ID:

26649

DISS Medical Gas Outlet Conversion Kit

Enhance your veterinary facility’s medical gas delivery with the DISS Medical Gas Outlet Conversion Kit from Infinium Veterinary. This advanced conversion solution upgrades existing outlets to reliable DISS connections, ensuring secure and efficient gas supply for oxygen, vacuum, and other essential services in animal health environments. Designed for seamless integration, it supports high-flow demands and easy maintenance, optimizing safety and performance in veterinary practices and hospitals.

Description

The DISS Medical Gas Outlet Conversion Kit offers a sophisticated solution for upgrading outdated or incompatible medical gas outlets in veterinary settings. By converting existing systems to the reliable DISS standard, this kit ensures consistent and secure connections for critical gases such as oxygen and vacuum, which are vital for anesthesia, respiratory support, and surgical procedures in animal care. Infinium Veterinary provides this kit for quotation, delivering product details focused on enhancing operational efficiency and patient safety without committing to external services or guarantees.

Advantages

Upgrading to this conversion kit brings numerous benefits to veterinary professionals, including improved flow rates to meet the demands of high-volume animal health procedures, reduced leakage risks for a safer environment, and the ability to support dispensing equipment directly without additional hardware. It simplifies maintenance by allowing service without disrupting gas supply, minimizing downtime in busy clinics. Additionally, the robust design strengthens connections to prevent accidental disconnects, ensuring reliability during critical interventions in veterinary hospitals.

Features

  • Unique patented valve cartridge for enhanced durability and performance
  • Gas-specific DISS outlet body tailored to individual service needs
  • Double permanent identification on connector and faceplate for quick recognition
  • Full faceplate color coding for intuitive use and error reduction
  • Strengthened connections to eliminate unintended disconnects
  • Direct support for dispensing equipment without requiring extra brackets
  • Unitized primary check valve cartridge for easy servicing
  • Automatic secondary check valve for positive pressure gases to prevent free flow
  • No secondary check for vacuum services, optimizing design efficiency
  • Permanently embossed gas service name on sub-mounting plate and outlet body
  • Cleaned for oxygen service in accordance with CGA Pamphlet G-4.1 standards
  • Double O-ring seal in conversion body, serviceable without gas shutdown
  • Capable of supporting 10 pounds at 2 inches from nameplate without leaking
  • White plastic surface mount housing with 2.375-inch front box height

This kit is available in various models to accommodate different existing outlet types and gas services. For instance, models like F3816 convert Chemetron/NCG 5/8-27 outlets for medical air, while F4016 handles oxygen conversions from the same base. Nitrogen-specific options such as F3916 ensure precise adaptations, and vacuum models like F4116 provide reliable suction upgrades. Nitrous oxide variants, including F3116, cater to anesthesia needs. XC Series models, such as XC4304-A, offer common back conversions for Schrader 1/4 NPT outlets in nitrous oxide, with similar adaptations for medical air (XC4316-A), vacuum (XC4322-A), and oxygen (XC4324-A). These variations differentiate by thread size, existing brand compatibility (e.g., Ohmeda, Oxequip, Puritan), and gas type, allowing customized upgrades to DISS standards in veterinary infrastructures.

Veterinary Applications

In veterinary practices and hospitals, the DISS Medical Gas Outlet Conversion Kit is essential for modernizing gas delivery systems used in surgical suites, recovery areas, and intensive care units. It facilitates the safe administration of oxygen during anesthesia and post-operative care for animals ranging from small pets to large livestock, while vacuum outlets support aspiration and suction needs in procedures like dental work or wound management. By converting legacy outlets, veterinary teams can achieve higher flow rates and better reliability, which is crucial for emergency responses and routine treatments in animal health settings, ultimately improving outcomes for patients in diverse clinical scenarios.

ParameterValue
Unique patented valve cartridgeYes
Gas specific DISS outlet bodyYes
Double permanent identification for the user – service identified on both connector and faceplateYes
Full faceplate color codingYes
Strength of connections eliminates unintended disconnectsYes
Provides support for dispensing equipment without the use of additional bracketsYes
The medical gas wall outlets shall be Frontall DISS Medical Gas OutletsYes
The outlets shall incorporate full faceplate sized color codingYes
The outlets shall be capable of supporting dispensing equipment without the use of slide bracketsYes
The medical gas outlets shall be designed so that, once installed, routine service of both the primary and secondary check valves can be accomplished without removing the nameplate or gas specific portionsYes
The primary check valve shall be unitized and of the cartridge typeYes
So that the primary check can be removed for service without shutting off the gas supply to the outlet, the secondary check valve shall operate automatically to stop the free flow of the pressure gasYes
There shall be no secondary check for vacuum serviceYes
Medical gas outlets that require the removal of the nameplate or gas specific components for routine service shall not be acceptableYes
The outlet nameplate shall be permanently color coded and sealed behind a Lexan protective coverYes
To prevent leaks within the finished wall, there shall be no rubber o-rings for a gas seal behind the faceplateYes
The name of the gas service shall be permanently embossed on the outlet sub-mounting plate and the chrome plated brass outlet bodyYes
Medical gas outlets shall be cleaned for oxygen service in accordance with the current Compressed Gas Association (CGA) Pamphlet G-4.1, capped and placed in a protective container for shipmentYes
The outlets shall be installed in strict accordance with manufacturer’s instructions, and tested before use in conformance with local and federal codesYes
Easy installationYes
100% tested for flow & leakageYes
Made in the U.S.A.Yes
The XC series medical gas outlet conversion kit shall be designed so that, once installed, Tri-Tech Medical Inc. standard X Series outlet front nameplate assemblies can be installed in them, ensuring a complete range of current new possible outlet connectionsYes
The XC series medical gas outlet conversion kit features a conversion outlet body that provides the secondary check valve, in positive pressure gas services only which stops the free flow of positive pressure gas servicesYes
The seal in the conversion outlet body shall be the Tri-Tech Medical Inc. double O-ring seal, which is serviceable without shutting off the gas service and, once the front nameplate is installed, is capable of supporting 10 pounds @ 2” from the nameplate without leakingYes
The XC series medical gas outlet conversion kit includes a white plastic surface mount housing, upon which the front nameplate mounts, front box height 2.375”Yes
Outlet front nameplates are purchased separatelyYes
Medical gas outlets and conversion outlet bodies shall be cleaned for Oxygen service in accordance with the current Compressed Gas Association (CGA) pamphlet G-4.1, and placed in a protective sealed bag for shipmentYes
Conversions and outlet front nameplate assemblies shall be installed in strict accordance with manufacturer’s instructions, and tested before use in conformance with local and federal codesYes
Front Box Height2.375"

Model-Specific Specifications

ModelGas ServiceExisting OutletThread
F3816Medical AirChemetron/NCG5/8-27
F3916NitrogenChemetron/NCG5/8-27
F3116Nitrous OxideChemetron/NCG5/8-27
F4016OxygenChemetron/NCG5/8-27
F4116VacuumChemetron/NCG5/8-27
XC4304-ANitrous OxideSchrader1/4 NPT
XC4316-AMedical AirSchrader1/4 NPT
XC4322-AMedical VacuumSchrader1/4 NPT
XC4324-AOxygenSchrader1/4 NPT

Recommended Accessories

  • Trim Plates: Custom-made plates for multiple outlets, installed against the wall behind faceplates based on distance between outlet centers
  • Standard Outlet Front Finishing Kit/Nameplate Assemblies: Durable scratch-resistant labels with permanent gradate NFPA color coding, available in Allied/Chemetron style QC, Frontall DISS, Ohio/Ohmeda style QC, and Puritan style QC for various gases
  • White Plastic Surface Mount Housing: Included in XC series for mounting front nameplates, with 2.375-inch height