Hallowell 2002 PRO Veterinary Anesthesia Ventilator

Web ID:

23979

Hallowell 2002 PRO Veterinary Anesthesia Ventilator

A Low Supply Gas Pressure Alarm, now standard on all units, will sound when the supply gas pressure falls below 35 psi, 2.4bar and stops around 42 psi. The normal supply gas operating pressure is 50psi or 3.5bar. It is not until 35psi or 2.4bar that the ventilators delivered volume will begin to drop off proportionally with the waning supply pressure.

The Hallowell Model 2002 became our best-selling ventilator with the addition of a fine volume control valve. Now with the Model 2002PRO we have simplified the Model 2002 with the replacement of the two volume control valve knobs to one volume control valve knob which has the functionality of both.

Available with any combination of the following bellows:

  • 0-300ml – Pediatric
  • 300-1600ml – Standard
  • 1600-3000ml – Extra Large

Description

Hallowell Model 2002 PRO Veterinary Anesthesia Ventilator with Variable Bellow Options

A Low Supply Gas Pressure Alarm, now standard on all units, will sound when the supply gas pressure falls below 35 psi, 2.4bar and stops around 42 psi. The normal supply gas operating pressure is 50psi or 3.5bar. It is not until 35psi or 2.4bar that the ventilators delivered volume will begin to drop off proportionally with the waning supply pressure.

The Hallowell Model 2002 became our best-selling ventilator with the addition of a fine volume control valve. Now with the Model 2002PRO we have simplified the Model 2002 with the replacement of the two volume control valve knobs to one volume control valve knob which has the functionality of both.

The single valve turns a total of nine and a half times; the first two and a half turns utilizing the slight, minute changes for pediatric animal patients, and the remainder of the rotations for use with the adult and extra large bellows and housings. All other parts and accessories for the Hallowell Model 2002PRO have remained the same.

Model Features

Electronic control — Eliminates the substantial driving gas required to operate pneumatically controlled ventilators.  It is time-cycled, and pressure limited.

Time cycled — Ensures consistently spaced breaths. The possibility of stacking breaths or auto-PEEP is eliminated by keeping the I:E ratio constant at 1:2. This means that regardless of the respiratory rate setting two-thirds of the breath will remain for expiration. The respiratory rate is adjustable from 6 – 40 breaths per minute (BPM).

Volume constant — Ensures that each delivered breath will have essentially the same volume, independent of changes in animal patient compliance and airway resistance. The deliverable tidal volume (TV) range is from approximately 20 cc to 3,000 cc.

Pressure Limited — Provides for animal patient safety by limiting the maximum working pressure (MWPL) to a user adjustable pressure range of 10 – 60 cm H2O.

Dual Airway Pressure Alarms — monitor and sound when the peak inspiratory pressure (PIP) of any breath either exceeds the preset maximum working pressure limit (MWPL); or fails to reach 6 cm H2O as in the case of a disconnect.

The Hallowell Model 2024 PRO does not replace the Hallowell Model 2002 PRO, the functionality of both units is still top of the line for veterinarian use. Technical Services, Replacement Parts and Repairs remain available and will continue for all HEMC units still in service.

Available with any combination of the following bellows:

  • 0-300ml – Pediatric
  • 300-1600ml – Standard
  • 1600-3000ml – Extra Large

Included Accessory Kit

Pro Series Ventilator Accessory Kit

Kit includes:

  • (1) 4ft. DISS O2 Supply Hose
  • (1) O2 DISS inline pressure gauge
  • (1) DISS O2 Demand Wye
  • (1) O2 DISS Male Coupler

The gauge can also be ordered separately.