MedTouch Medical Gas Master Alarm Panel

Web ID:

26413

MedTouch Medical Gas Master Alarm Panel

Enhance veterinary facility safety with the Tri-Tech Med Touch Master Alarm Panel from Infinium Veterinary. This advanced system monitors up to 128 remote medical gas source signals, providing real-time normal and alarm conditions via a 2.85-inch LCD touchscreen for reliable oversight in animal health environments, ensuring compliance with NFPA 99 standards and supporting seamless operations in clinics and hospitals.

Description

The Tri-Tech Med Touch Master Alarm Panel, available for quotation through Infinium Veterinary, delivers comprehensive monitoring for medical gas systems in veterinary practices. This microprocessor-controlled panel displays normal and alarm conditions from up to 128 remote signals, utilizing a 2.85-inch LCD touchscreen for intuitive programming and real-time digital pressure readouts. Ideal for animal health facilities, it supports compliance with NFPA 99 requirements while offering customizable features to maintain operational efficiency and safety during veterinary procedures.

Advantages

The Tri-Tech Med Touch Master Alarm Panel offers streamlined integration into veterinary gas infrastructure, reducing setup time and enhancing system reliability for budget-conscious animal health operations. It provides customizable emergency instructions and alarm notifications, empowering veterinary teams to respond swiftly to pressure deviations and maintain uninterrupted care in surgical suites and recovery areas. With options for wireless models and building management system interfaces, it adds flexibility and scalability, delivering proven performance that aligns with the demands of modern veterinary hospitals without unnecessary complexity.

Key Features

  • Monitors and displays normal and alarm conditions from up to 128 remote medical gas source signals.
  • 2.85-inch LCD touchscreen for up to 8 normal and alarm conditions per group, with digital pressure display for transducer inputs.
  • Supports pressure switch, transducer, and 4-20 mA sensor inputs for versatile monitoring.
  • Programmable without tools, with user-adjustable high/low set points and alarm repeat features.
  • Green normal and red alarm indicators for each gas service, with blinking displays and customizable emergency instructions.
  • Self-diagnostic error messages, event history logging, and audio/visual alarm indicators.
  • Compliant with NFPA 99, ETL listed to UL 1069 and CSA C22.2 #205.
  • Pre-loaded NFPA and ISO gas labels, multiple languages (English, English/French, English/Spanish), and editable text.
  • Optional Ethernet board for webserver access, event logging, text/email notifications to up to 5 addresses, and Modbus/BACnet interfaces.
  • Wireless models available for minimal low-voltage wiring.
  • Dry contacts for general fault conditions and hinged frame for easy accessibility.
  • Available in 2-slot (up to 32 signals), 3-slot (up to 64 signals), and 5-slot (up to 128 signals) configurations.

Veterinary Applications

In veterinary practices and animal health facilities, the Tri-Tech Med Touch Master Alarm Panel plays a crucial role in overseeing medical gas supplies essential for anesthesia, oxygen therapy, and surgical procedures. By providing real-time monitoring of pressures and vacuum levels across multiple zones, it helps prevent disruptions during critical interventions, such as emergency surgeries or routine examinations, allowing veterinary professionals to focus on optimal animal care outcomes. Its scalable design suits small clinics to large hospitals, ensuring reliable gas system performance that supports compliance and enhances overall facility safety protocols.

ParameterValue (Imperial)Value (Metric)
Display Type2.85 in LCD Touchscreen72.4 mm LCD Touchscreen
Number of SignalsUp to 128Up to 128
Input Voltage120-240 VAC, 50-60 Hz120-240 VAC, 50-60 Hz
Pressure UnitsPSI, inHgkPa, BAR, mmHg
Alarm IndicatorsVisual (Green/Red LCD), AudibleVisual (Green/Red LCD), Audible
ComplianceNFPA 99, ETL to UL 1069, CSA C22.2 #205NFPA 99, ETL to UL 1069, CSA C22.2 #205
Sensor InputsPressure Switch, Transducer (up to 4 gases), 4-20 mAPressure Switch, Transducer (up to 4 gases), 4-20 mA

2-Slot Model Specifications

ParameterValue (Imperial)Value (Metric)
Master BoardsUp to 4 (32 signals)Up to 4 (32 signals)

3-Slot Model Specifications

ParameterValue (Imperial)Value (Metric)
Master BoardsUp to 8 (64 signals)Up to 8 (64 signals)

5-Slot Model Specifications

ParameterValue (Imperial)Value (Metric)
Master BoardsUp to 16 (128 signals)Up to 16 (128 signals)

Recommended Accessories

  • Pressure Switches: Sold separately for monitoring specific gas pressures.
  • Transducers: Available separately to provide digital pressure readouts for up to 4 gases.
  • DISS Union Check Valve Connectors: Optional components for secure gas line connections.
  • Ethernet Board (35-3032 Kit): Provides webserver access, event logging, text/email notifications, and Modbus interface.
  • BACnet Module (35-3035 Kit): Enables BACnet interface with building management systems (requires 35-3032 and 35-3033 kits).
  • Ethernet Programming Kit (35-3033): Required for installing Ethernet or BACnet options, one per facility.
  • TAV-1 Remote Audio/Visual Alarm: Domestic version with transformer (90-264 VAC, 50-60 Hz, 5 VDC), high-intensity LED lights, 85 dBA buzzer, for cylinder depletion warnings.
  • TAV-2 Remote Audio/Visual Alarm: International version with transformer (100-240 VAC, 50-60 Hz, 5 VDC) and interchangeable plugs, for global use in monitoring gas systems.
  • Zone Expansion Modules: For adding signal points in larger configurations.
  • Remote Sensor Kits: Extend monitoring to multi-room veterinary setups.
  • Backup Battery Option: Ensures continued operation during power interruptions in critical areas.